1K-2 Exhaust System:
Exhaust Pipe / Muffler Removal and Installation
B705H11B06002
Removal
1) Remove the HO2 sensor lead wire coupler (1).
2) Loosen the exhaust pipe connecting bolt (2).
3) Remove the muffler mounting bolts (3) and remove
the muffler (4).
4) Remove the HO2 sensor (5).
5) Remove the exhaust pipe (6).
6) Remove the exhaust pipe gasket (7).
1
I705H11B0001-01
2
I705H11B0002-01
3
4
I705H11B0003-01
5
I705H11B0004-01
6
I705H11B0005-01
7
I705H11B0006-01