1K-4 Exhaust System:
Exhaust System Inspection
B705H11B06005
Inspect the exhaust pipe connection and muffler
connection for exhaust gas leakage and mounting
condition. If any defect is found, replace the exhaust
pipe or muffler with a new one.
Check the exhaust pipe bolts, exhaust pipe connecting
bolt and muffler mounting bolts are tightened to their
specified torque.
Tightening torque
Exhaust pipe bolt (a): 23 N·m (2.3 kgf-m, 16.5 lb-ft)
Exhaust pipe connecting bolt (b): 23 N·m (2.3 kgf-
m, 16.5 lb-ft)
Muffler mounting bolt (c): 23 N·m (2.3 kgf-m, 16.5 lb-
ft)
HO2 Sensor Inspection
B705H11B06006
Refer to “HO2 Sensor Inspection in Section 1C
(Page1C-6)”.
(a)
3
I705H11B0009-02
(c)
5
(d)
6
I705H11B0011-02