General Information
Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only
Service Manual
1-70
Operating Environment
Safety / Environment Conditions
Noise Levels
Characteristic Specification
Installation Temperature /
Humidity
Installation temperature and humidity on the condition without condensation is
as follows.
Operating: 10-32°C, 10-85%RH (No condensation)
Storage: minus 20-40°C, 5-85%RH (No condensation)
Installation Altitude 0 to 3,100m
Installation Horizontality Longitudinal levelness of table surface on which the printer is installed: 1 degree
or under
Lateral levelness of table surface on which the printer is installed: 1 degree or
under
Storage Temperature of a
Toner Cartridge
The guaranteed period of the Toner Cartridge before unpacked is as follows:
Normal conditions: 24 months under 0 to 35°C, 15 to 80% RH.
Harsh conditions: 1 month under -20 to 0°C and 35 to 40°C, 5 to 15% RH and 80
to 95% RH.
The storage altitude shall be 0 to 3,100m. Can be extended to 0 to 15,000m
when shipped by air.
(Provided that the cargo bay is pressurized to 70.9275Kpa or higher.
100-127V M/C 220-240V M/C
Safety Standard UL60950-1, CSA 22.2 60950 IEC60950-1 / EN60950-1
Laser Safety Standard FDA21CFR Chapter 1, Subchapter J,
Section 1010, 1040
IEC60825-1 Amendment 1 + Amendment 2 /
EN60825-1 Amendment 1 + Amendment 2
Class 1 Laser Product
EMI FCC Part15 Subpart B, Class B EN55022:2006, Class B
Mode
Sound Power Level (B)
LWA LWAD
Running Color 7.15 7.2
B&W 6.95 7.25
Standby Color 4.69 4.8
B&W 4.69 4.99