SETTINGS screen page
This screen is used to adjust some control unit pa-
rameters.
ADJUSTMENTS
Diagnostic tool characteristics Value/example Units of
measure
ment
Notes
Disabling of VR-shut down - - -
Enabling of VR-shut down - - -
EVAC and wires - - -
ABS bleeding phase 1 - - -
ABS bleeding phase 2 - - -
ABS bleeding phase 3 - - -
ABS bleeding phase 4 - - -
Stores bleeding date - - -
Production date - - -
Writing of VIN code - - -
Diagnosis
VOLTAGE ERRORS
C1058 Low power supply voltage
C1059 High power supply voltage
Cause of error
Power supply voltage below minimum threshold or above maximum threshold detected on PIN 4 or on
PIN 18 of the ABS control unit.
Troubleshooting
- Check that the voltage regulator is working correctly.
- Check the battery.
CONFIGURATION ERRORS
RS 125 - Tuono 125 - Euro 4 Braking system
BRAK SYS - 293