189
Note The time is provided by the network. If the time is not what you expect, contact your network
provider.
Parameter range
0 - 1
Value Description
0 The response is the number of seconds since 2000-01-01 00:00:00, as a 32-
bit number. This is the default.
1 The response is the current date and time in ISO 8601 format. For example,
"2018-12-25T22:00:05".
Note You can also send DT, which acts like DT=0.
Default
0
AN (Access Point Name)
Specifies the packet data network that the modem uses for Internet connectivity. This information is
provided by your cellular network operator. After you set this value, applying changes with AC (Apply
Changes) or CN (Exit Command mode) triggers a network reset.
Parameter range
1 - 100 ASCII characters
Default
-
OA (Operating APN)
Reads the APN value currently configured in the cellular component.
Parameter range
ASCII characters
Default
N/A
AM (Airplane Mode)
When set, the cellular component of the XBee Smart Modem is fully turned off and no access to the
cellular network is performed or possible.
Parameter range
0 - 1
0 = Normal operation

Table of Contents