AT commands Serial interfacing commands
Digi XBe 3 Cellular LTE Cat 1 AT&T Smart Modem User Guide
200
Default
0x00
SB (Stop Bits)
Sets or displays the number of stop bits for UART communications.
Parameter range
0 - 1
Parameter Configuration
0 One stop bit
1 Two stop bits
Default
0
RO (Packetization Timeout)
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
RF transmission also starts after the maximum packet size for the selected protocol is received in the
UART receive buffer.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
Parameter range
0 - 0xFF (x character times)
Default
3
TD (Text Delimiter)
The ASCII character used as a text delimiter for Transparent mode. When you select a character,
information received over the serial port in Transparent mode is not transmitted until that character
is received. To use a carriage return, set to 0xD. Set to zero to disable text delimiter checking.
Parameter range
0 - 0xFF
Default
0x0
FT (Flow Control Threshold)
Set or display the flow control threshold.
The device de-asserts CTS when FT bytes are in the UART receive buffer.