API frames Socket Option Response - 0xC1
Digi XBe 3 Cellular LTE Cat 1 AT&T Smart Modem User Guide
269
Socket Option Response - 0xC1
Description
Reports the status of requests made with the Socket Option Request (0x41) frame.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Field name
Field
value Data type Description
Frame type 0xC1 Byte
Frame ID Byte Identifier provided in request.
Socket ID Byte The socket IDfor which modification was
requested.
Option ID Byte Identifier of the parameter requested.
Status Byte
0x00: Success
0x01: Invalid parameters
0x02: Failed to retrieve option value
0x20: Bad socket ID
Option Data Variable Current effective value of the option. This
field is only present if the corresponding
request was a query (empty value).