The following table describes the fields in the GETrequest.
Field HEX Bits Meaning
Ver 44 01 Version 01, which is mandatory here.
T 00 Type 0: confirmable.
TKL 0100 Token length: 4.
Code 01 000 00001 Code: 0.01, which indicates the GET method.
Message ID C4 09 2 Bytes equal
to hex at left
Message ID. The response message will have the
same ID. This can help out identification.
Token 74 65 73 74 4 Bytes equal
to hex at left
Token. The response message will have the same
token. This can help out identification.
Option delta B7 1011 Delta option: 11 indicates the option data is Uri-Path.
Optionlength 0111 Delta length: 7 indicates there are 7 bytes of data
following as a part of this delta option.
Option value 65 78 61 6D
70 6C 65
7 Bytes equal
to hex at left
Example.
Configure the device
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2.
Open XCTU and click the Configuration working mode button.
3. Add the XBee Smart Modem to XCTU; see Add a device to XCTU.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5.
To switch to UDPcommunication, in the IP field, select 0 and click the Write button .
6. To set the target IP address that the XBee Smart Modem will talk to, in the DL field type
52.43.121.77and click the Write button . A CoAP server is publicly available at address
52.43.121.77.
7. To set the XBee Smart Modem to send data to port 5683 in decimal, in the DEfield, type 1633
and click the Write button.
8. To move into Transparent mode, in the APfield, select 0 and click the Write button.
9. Wait for the AI (Association Indication) value to change to 0 (Connected to the Internet). You
can click Read to get an update on the AI value.
Example: manually perform a CoAPrequest
Follow the steps in Configure the device prior to this example. This example performs the CoAP
GETrequest:

Table of Contents

Other manuals for Digi XBee 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee 3 and is the answer not in the manual?

Digi XBee 3 Specifications

General IconGeneral
BrandDigi
ModelXBee 3
CategoryModem
LanguageEnglish

Related product manuals