0xBB8 (5 minutes)
TS (IP Server Connection Timeout)
The IP server connection timeout. If no activity for this timeout then the connection is closed. When
set to 0 the connection is closed immediately after data is sent.]
Parameter Range
10 - 0xFFFF; (x 100 ms)
Default
3000
DO (Device Options)
Enables and disables special features on the XBee Smart Modem.
Bit 0 - Remote Manager support
Controls whether Remote Manager is active.
If the XBee Smart Modem cannot establish a connection with Remote Manager, it waits 30 seconds
before trying again. On each successive connection failure, the wait time doubles (60 seconds, 120,
240, and so on) up to a maximum of 1 hour. This time resets to 30 seconds once the connection to
Remote Manager succeeds or if the device is reset.
Bits 1 - 7
Reserved
Range
0-7
Bitfield
Bit Description
0 Enable Remote Manager support
1-7 Reserved for future use
Default
1 (Bit 0 enabled)