10.7 Checking and changing Q parameters
Procedure
You can check Q parameters in all operating modes, and also edit
them.
If you are in a program run, interrupt it if required (e.g., by
pressing the NC STOPP key and the INTERNAL STOP soft key),
or stop the test run
To call the Q parameter functions, press the
Q INFO soft key or the Q key
The control lists all of the parameters and their
corresponding current values.
Use the arrow keys or the GOTO key to select
the desired parameter.
If you would like to change the value, press the
EDIT CURRENT FIELD soft key. Enter a new file
name and confirm with ENT
To leave the value unchanged, press the
PRESENT VALUE soft key or end the dialog with
the END key
All of the parameters with displayed comments are used
by the control within cycles or as transfer parameters.
If you want to check or edit local, global or string
parameters, press the SHOW PARAMETERS Q QL QR QS
soft key. The control then displays the specific
parameter type. The functions previously described also