Item Content
Serial Number # Serial product number (decimal, from 400001 to 499999)
IP Address IP address
Output e
xample: xxx.xxx.xxx.xxx (decimal, 0 to 255)
Subnet Mask Subnet mask
Output example: xxx.xxx.xxx.xxx (decimal, 0 to 255)
Number of CUs Number of CUs (decimal, 0 to 64)
Number of DKBs Number of DKBs (decimal, 0 to 8)
Zero (0) is sometimes displayed if an HDD is not installed.
Conguration Type Conguration type
Output example: PCM
Model Storage system model: S, M, or H
Unied Mode Unied Mode of the storage system.
■
On: Operating with Unied Mode
■
O: Not operating with Unied Mode
This item is not displayed for VSP G200.
Notes:
■
To determine if the model type is VSP G200, see
PpInfo.csv (on page 282) .
●
VSP G200
: Install is Enabled for Model upgrade license
■
To determine whether the model type is VSP G400, VSP F400, VSP G600, or VSP F600, see
PpInfo.csv (on page 282) .
●
VSP G400
: Install is Disabled for both Model upgrade license and All Flash Array
●
VSP F400: Install is Disabled for Model upgrade license and Install is Enabled for All Flash Array
●
VSP G600: Install is Enabled for Model upgrade license and Install is Disabled for All Flash Array
●
VSP F600: Install is Enabled for both Model upgrade license and All Flash Array
■
To determine whether the model type is VSP G800 or VSP F800, see
PpInfo.csv (on page 282) .
●
VSP G800
: Install is Disabled for All Flash Array
●
VSP F800: Install is Enabled for All Flash Array
DkuTempAveInfo.csv
This CSV
le contains information about DB temperature for every two hours. A record is
DB temperature information obtained from the environment monitor. A record output to
the rst line shows the latest temperature information. Because DB temperature
information is measured by DBPS, items are displayed in this unit*.
DkuTempAveInfo.csv
Appendix A: Examples of storage conguration reports