Item Description
Electric power maximum
value
Maximum value of electric power (W)
Electric power minimum
value
Minimum value of electric power (W)
In the follo
wing cases, a lower value might be temporarily displayed:
â–
When the storage system is starting up
â–
Right after replacing storage system parts
â–
During or after microcode update
DKC0 CL1 Temperature
average
DKC0: Average temperature of CL1 (°C)
DKC0 CL1 Temperature
maximum value
DKC0: Maximum temperature of CL1 (°C)
DKC0 CL1 Temperature
minimum value
DKC0: Minimum temperature of CL1 (°C)
DKC0 CL2 Temperature
average
DKC0: Average temperature of CL2 (°C)
DKC0 CL2 Temperature
maximum value
DKC0: Maximum temperature of CL2 (°C)
DKC0 CL2 Temperature
minimum value
DKC0: Minimum temperature of CL2 (°C)
FcSpNameInfo.csv
This CSV
î ´le contains information about Fibre Channel Security Protocols (FCSPs). A
record is created for each initiator (host).
For details of port setting, see the Provisioning Guide. Information about the NAS module
is not displayed in this CSV î ´le.
Table 29 FcSpNameInfo.csv î ´le (Title: <<FC-SP Name Information>>)
Item Content
Port Port name
Host Group Host group name
Target Username WWN information about the storage system required for authentication
(16-digit he
xadecimal number)
FcSpNameInfo.csv
Appendix A: Examples of storage conî ´guration reports