9: Administration
SGX 5150 IoT Device Gateway User Guide 114
TM
To access System settings:
Using Web Manager
To access System settings with options to set up a reboot schedule, reboot, restore factory
defaults, upload new firmware, reboot the standalone firmware installer, update the system
name (long or short names) or to view the current configuration, on the Administration page,
click System.
Using the CLI
To reboot or restore factory defaults, enter the System command level: enable
To setup a reboot schedule, update the system name (long or short names), enter the Device
command level: enable > device
Using XML
Include in your file: <configgroup name=”xml import control”>
Include in your file: <configgroup name="reboot schedule">
Include in your file: <configgroup name="device">
Terminal
You can configure whether each serial line or the Telnet/SSH server presents a CLI or a Login
Connect menu when a connection is made.
Table 9-46 Terminal on Network and Line Settings
Standalone Firmware
Installer
Click Reboot to Standalone Firmware Installer to reboot the SGX 5150
gateway to a standalone firmware installer mode. When the SGX 5150
gateway is rebooted, your browser should be refreshed and redirected to the
firmware installer page after 30 seconds. Upload and install new device
firmware from that page.
Short Name Enter a short name for the system name. A maximum of 32 characters are
allowed.
Long Name Enter a long name for the system name. A maximum of 64 characters are
allowed.
Terminal on Network
and Line Settings
Description
Terminal Type Enter text to describe the type of terminal. The text will be sent to a host via IAC.
Note: IAC means, “interpret as command.” It is a way to send commands over
the network such as send break or start echoing. IAC is only supported in
Telnet.
Login Connect Menu Select the interface to display when the user logs in. Choices are:
Enabled = shows the Login Connect Menu.
Disabled = shows the CLI (default)
System Settings Description

Table of Contents

Other manuals for Lantronix SGX 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SGX 5150 and is the answer not in the manual?

Lantronix SGX 5150 Specifications

General IconGeneral
CertificationFCC ICES-003:2012 RED 2014/53/EU, EMCD 2014/30/EU, EN 300 328 V1.9.1, EN 301 489-1 V1.9.2, EN301 489-17 V2.2.1, EN 301 893 V1.8.1, EN 62311: 2008 AS/NZS CISPR 22, AS/NZS 4268: A1: 2013, AS/NZS 2772.2VCCI EN 55022:2010, EN 55024:2010, EN 61000-3-2:A2 2009, EN 61000-3-3: 2008 UL 60950/CSA 22.2 No. 60950, IEC 60950 CE LVD 2014/35/EU
LED indicatorsYes
Power requirements9 - 30 VDC
Power over Ethernet (PoE)No
Power consumption (typical)1.9 W
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)5 - 95 %
Security algorithms802.1x RADIUS, AES, EAP-FAST, EAP-PEAP, EAP-TLS, EAP-TTLS, FIPS 140-2, MSCHAPv2, TKIP, WPA, WPA2, WPA2-PSK, WPS
Authentication methodRADIUS
Ethernet LAN (RJ-45) ports1
Supported protocolsIPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, (S)FTP
Frequency band2.4 / 5 GHz
Cabling technology10/100BASE-T(X)
Networking standardsIEEE 802.11a, IEEE 802.11ac, IEEE 802.11b, IEEE 802.11d, IEEE 802.11g, IEEE 802.11h, IEEE 802.11i, IEEE 802.11n, IEEE 802.1x, IEEE 802.3, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u
Ethernet LAN data rates10, 100 Mbit/s
Weight and Dimensions IconWeight and Dimensions
Weight350 g
Dimensions (WxDxH)110 x 89 x 26 mm