9: Administration
SGX 5150 IoT Device Gateway User Guide 99
TM
This page displays the configuration and status for MACH10 Line client.
Table 9-28 MACH10 Line
To Configure MACH10 USB 1
This page displays the configuration and status for MACH10 Line client.
Table 9-29 MACH10 Client USB
To Configure MACH10
Using Web Manager
To configure MACH10 Client, on the Administration page, click MACH10 > Client..
To configure MACH10 Line 1, on the Administration page, click MACH10 > Line 1.
To configure MACH10 Line 2, on the Administration page, click MACH10 > Line 2.
To configure MACH10 USB 1, on the Administration page, click MACH10 > USB 1.
Using the CLI
To enter the command level: enable > config > mach10
MACH10 Line Description
State Click to enable or disable the MACH10 line client.
Project Tag Enter the MACH10 Project Tag name.
Status Update
Interval
Enter the Status Update Interval in minutes. The status update interval is the
frequency in which the gateway will contact the MACH10 server.
Content Check
Interval
Enter the Content Check Interval in hours. The content check interval is the
frequency in which the gateway contacts the server for new content.
Command Deliminiter Enter the Command Delimiter for attached serial devices.
Note: Send delimiter before command and after response is received.
Local Port Enter the local port for the MACH10 client. When configured, a total of 16
consecutive ports will be reserved.
Submit (button) Click the Submit button to enter the settings. The Submit button appears when
new settings are entered.
MACH10 USB Description
State Click to enable or disable the MACH10 USB client.
Project Tag Enter the MACH10 Project Tag name.
Status Update
Interval
Enter the Status Update Interval in minutes. The status update interval is the
frequency in which the gateway will contact the MACH10 server.
Content Check
Interval
Enter the Content Check Interval in hours. The content check interval is the
frequency in which the gateway contacts the server for new content.
Command Deliminiter Enter the Command Delimiter for attached serial devices.
Note: Send delimiter before command and after response is received.
Local Port Enter the local port for MACH10 client. When configured, a total of 16 consecutive
ports will be reserved.

Table of Contents

Other manuals for Lantronix SGX 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SGX 5150 and is the answer not in the manual?

Lantronix SGX 5150 Specifications

General IconGeneral
CertificationFCC ICES-003:2012 RED 2014/53/EU, EMCD 2014/30/EU, EN 300 328 V1.9.1, EN 301 489-1 V1.9.2, EN301 489-17 V2.2.1, EN 301 893 V1.8.1, EN 62311: 2008 AS/NZS CISPR 22, AS/NZS 4268: A1: 2013, AS/NZS 2772.2VCCI EN 55022:2010, EN 55024:2010, EN 61000-3-2:A2 2009, EN 61000-3-3: 2008 UL 60950/CSA 22.2 No. 60950, IEC 60950 CE LVD 2014/35/EU
LED indicatorsYes
Power requirements9 - 30 VDC
Power over Ethernet (PoE)No
Power consumption (typical)1.9 W
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)5 - 95 %
Security algorithms802.1x RADIUS, AES, EAP-FAST, EAP-PEAP, EAP-TLS, EAP-TTLS, FIPS 140-2, MSCHAPv2, TKIP, WPA, WPA2, WPA2-PSK, WPS
Authentication methodRADIUS
Ethernet LAN (RJ-45) ports1
Supported protocolsIPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, (S)FTP
Frequency band2.4 / 5 GHz
Cabling technology10/100BASE-T(X)
Networking standardsIEEE 802.11a, IEEE 802.11ac, IEEE 802.11b, IEEE 802.11d, IEEE 802.11g, IEEE 802.11h, IEEE 802.11i, IEEE 802.11n, IEEE 802.1x, IEEE 802.3, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u
Ethernet LAN data rates10, 100 Mbit/s
Weight and Dimensions IconWeight and Dimensions
Weight350 g
Dimensions (WxDxH)110 x 89 x 26 mm