9: Administration
SGX 5150 IoT Device Gateway User Guide 115
TM
To Configure the Terminal Network Connection
Using Web Manager
To configure the Terminal on Network, click Administration in the header and select
Terminal > Network.
Using the CLI
To enter the Terminal Network command level: enable > config > terminal network
Using XML
Include in your file: <configgroup name="terminal" instance="network">
To Configure the Terminal Line or USB Connection
Note: The following section describes the steps to view and configure terminal line 1
settings; these steps apply to terminal line 2 and terminal line 3 of the SGX 5150 gateway.
Using Web Manager
To configure a particular Terminal Line, click Administration in the header and select
Terminal > Line 1.
To configure the Terminal USB, click Administration in the header and select Terminal >
USB 1.
Using the CLI
To enter the Terminal Line command level: enable > config > terminal 1
Exit Connect Menu Select whether to display a choice for the user to exit the Login Connect Menu
and reach the CLI. Choices are:
Enabled = a choice allows the user to exit to the CLI.
Disabled = there is no exit to the CLI (default)
Send Break Enter the Send Break control character received from the network on its way to
a serial line which would cause the line output to be forced inactive.
Example setting:
<Ctrl> Y
Blank the field to set to <None>.
Note: This field is not available for terminal network configuration.
Break Duration Specify the length of the spacing condition placed on the line when a break is
sent.
Note: This field is not available for terminal network configuration.
Echo Select whether to enable echo:
Enabled
Disabled
Note: Applies only to Connect Mode Telnet connections, not to Accept Mode.
Only disable Echo if your terminal echoes, in which case you will see double of
each character typed. Default is enabled.
Terminal on Network
and Line Settings
Description

Table of Contents

Other manuals for Lantronix SGX 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SGX 5150 and is the answer not in the manual?

Lantronix SGX 5150 Specifications

General IconGeneral
CertificationFCC ICES-003:2012 RED 2014/53/EU, EMCD 2014/30/EU, EN 300 328 V1.9.1, EN 301 489-1 V1.9.2, EN301 489-17 V2.2.1, EN 301 893 V1.8.1, EN 62311: 2008 AS/NZS CISPR 22, AS/NZS 4268: A1: 2013, AS/NZS 2772.2VCCI EN 55022:2010, EN 55024:2010, EN 61000-3-2:A2 2009, EN 61000-3-3: 2008 UL 60950/CSA 22.2 No. 60950, IEC 60950 CE LVD 2014/35/EU
LED indicatorsYes
Power requirements9 - 30 VDC
Power over Ethernet (PoE)No
Power consumption (typical)1.9 W
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)5 - 95 %
Security algorithms802.1x RADIUS, AES, EAP-FAST, EAP-PEAP, EAP-TLS, EAP-TTLS, FIPS 140-2, MSCHAPv2, TKIP, WPA, WPA2, WPA2-PSK, WPS
Authentication methodRADIUS
Ethernet LAN (RJ-45) ports1
Supported protocolsIPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, (S)FTP
Frequency band2.4 / 5 GHz
Cabling technology10/100BASE-T(X)
Networking standardsIEEE 802.11a, IEEE 802.11ac, IEEE 802.11b, IEEE 802.11d, IEEE 802.11g, IEEE 802.11h, IEEE 802.11i, IEEE 802.11n, IEEE 802.1x, IEEE 802.3, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u
Ethernet LAN data rates10, 100 Mbit/s
Weight and Dimensions IconWeight and Dimensions
Weight350 g
Dimensions (WxDxH)110 x 89 x 26 mm

Related product manuals