SLC™ Console Manager User Guide 106
Device Commands
The following CLI commands correspond to the web page entries described above.
To send commands to (or control) a device connected to an SLC device port over the serial
port:
Note: Currently the only devices supported for this type of interaction are the SLP,
ServerTech CDU and Sensorsoft devices.
set command
Syntax
set command <Device Port # or Name or List> <one or more parameters>
Parameters
slp|servertech auth login <User Login>
Establishes the authentication information to log into the SLP or ServerTech CDU
attached to the device port.
slp|servertech restart
Issues the CLI command the SLP or ServerTech CDU uses to restart itself.
slp|servertech outletcontrol state <on|off|cyclepower> [outlet <Outlet
#>][tower <A|B>]
Outlet # is 1-8 for SLP8 and 1-16 for SLP16. For the ServerTech CDU, the valid range of
outlets is specified by the number of outlets settings (for Tower A) or number of expansion
outlets settings (for Tower B) - see below.
The outletcontrol parameters control individual outlets.
slp|servertech outletstate [outlet <Outlet #>] [tower <A|B>]
The outletstate parameter shows the state of all outlets or a single outlet.
slp|servertech envmon
Displays the environmental status (e.g., temperature and humidity) of the SLP or
ServerTech CDU.
slp|servertech infeedstatus
Displays the infeed status and load of the SLP or ServerTech CDU.
slp|servertech system
Displays the system configuration information, such as firmware, revision and uptime.
slp|servertech config [prompt <Command Prompt>]
Enter the prompt displayed by the SLP or ServerTech CDU device. This will default to a typical
prompt for an SLP or ServerTech CDU. If you are unable to control the SLP or ServerTech CDU
device, verify that the prompt is set to the right value.
[numoutlets <Number of Outlets>]
[numexpoutlets <Number of Expansion Outlets>]
Enter the number of outlets for a ServerTech CDU main unit or the number of outlets for a
Server Tech CDU expansion unit. This setting is not applicable for an SLP.
sensorsoft lowtemp <Low Temperature in C.>

Table of Contents

Other manuals for Lantronix SLC8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC8 and is the answer not in the manual?

Lantronix SLC8 Specifications

General IconGeneral
BrandLantronix
ModelSLC8
CategoryServer
LanguageEnglish

Related product manuals