Function introduction
AFG31000 Series Arbitrary Function Generator User's Manual 103
Sequence table
Sequence table
Sequence mode has the following options:
Event selection (for Wait/Jump): Off or Timer, External trigger, SCPI command, Manual.
Wait: If Wait is On, the waveform output is held until aWait event happens, then the
waveform output starts.
Repeat: Defines how many times the waveform in the entry is repeated, (1 to 1,000,000, or
infinite cycles).
Jump: If Jump is On, the current waveform output is interrupted when a Jump event happens
and the sequencer jumps to the Jump address immediately.
Goto: Once the current waveform repetition is complete (without being interrupted), the
sequencer goes to the Goto address. By default, the address is Next (current entry address +
1).
Figure 86: Advanced table