1-119
IM 04L51B01-01EN
Configuring the GX/GP and Viewing the Settings
1
2
3
4
5
App
Index
1.11 SettingMeasurementConditions(Scaninterval,
A/Dintegrate,etc.)
Set the scan interval, A/D integrate, measurement groups, etc.
1.11.1 Setting the Scan Interval
When the measurement mode is Dual interval, see page 1-137 in section 1.13, “Configuring
the Dual Interval Settings (Release number 4 and later)”.
Path
GX/GP: MENU key > Browse tab > Setting > Setting menu Measurement settings
Web application: Config. tab > Measurement settings > Scan interval
Hardware configurator: Measurement settings > Scan interval
Description
Scan interval
Setup Item Selectable Range or Options Default Value
Scan interval 1ms
4
, 2ms
4
, 5ms
4
, 10ms
4
, 20ms
4
, 50ms
4
,
100ms
1, 3
, 200ms
1, 3
, 500ms
1
, 1s, 2s, 5s
1s
2
1 Cannot be specified if an electromagnetic relay type (type suffix code -T1) analog input module
is in use (configured).
2 2 s if an electromagnetic relay type analog input module is in use.
3 Cannot be specified if a low withstand voltage relay type (type suffix code -L1) analog input
module is in use (configured).
4 You can set this when the measurement mode is High speed and a high-speed universal type
module is detected
Scan interval
Set the scan interval. The scan intervals that you can set are displayed depending on the
installed modules.
When the measurement mode is High speed and the scan interval is 1 ms or 2 ms, the
following limitations apply to the number of valid channels of the high-speed AI module.
Scan interval Channel limitations
1
1 ms All channels except channel 1 of each module are set to Skip.
2 ms Channels 3 and 4 of each module are set to Skip.
1 Channels set to skip as a result of changing the scan interval are not changed from
display group channel settings or recording channel settings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX20 and is the answer not in the manual?

YOKOGAWA GX20 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX20
CategoryRecording Equipment
LanguageEnglish

Related product manuals