1-154
IM 04L51B01-01EN
1.16.2 Setting the Channels to Output Reports
Path
GX/GP: MENU key > Browse tab > Setting > Setting menu Report settings > Report
channel settings
Web application: Config. tab > Report settings > Report channel settings
Hardware configurator: Report settings > Report channel settings
Description
Setup Item Selectable Range or Options Default Value
Report channel number GX20/GP20: 1 to 60
GX10/GP10: 1 to 50
1
* There are limits to the number of report channels depending on the measurement mode and
scan interval. For details, see “Explanation.”
Report channel number
Select the report channel number. The GX/GP generates reports in order by this number.
Report channel
Setup Item Selectable Range or Options Default Value
Channel type I/O channel, Math channel, Communication
channel, Off
—
Channel no
1
Channels that you can set —
Sum scale
1
Off, /s, /min, /h, /day —
1 Appears when the channel type is not set to Off.
Channel type
Set the channel type to assign to the report channel.
Channel no
Set the channel number to assign to the report channel. All channels can be assigned, but
reports are not created for channels set to Skip or Off even if they are assigned.
Sum scale
Set the sum scale to match the unit of the measured values.
Example: If the unit of the measured value is “m
3
/min,” select /min.
Off: The measured data is summed as-is once per scan interval.
1.16ConfiguringtheReportFunction(/MToption)