1-186
IM 04L51B01-01EN
E-mailcontents
Setup Item Selectable Range or Options Default Value
Header
Character string (up to 128,
)
—
Include source URL Off, On Off
Header
Sets the mail header.
Include source URL
Set this to On to include the source URL. The URL is attached when the Web server is
enabled.
Alarm settings
Setup Item Selectable Range or Options Default Value
Alarm notification Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2 Off
Detection
1, 4
Channel, Alarm level Channel
Channel set
2
Up to 50 channels; I/O channels, Math channels,
Communication channels
—
Detection alarm level 1
3, 4
Off, On Off
Detection alarm level 2
3, 4
Off, On Off
Detection alarm level 3
3, 4
Off, On Off
Detection alarm level 4
3, 4
Off, On Off
Attach instantaneous data
1
Off, On Off
Send alarm action
1
Occurrence & Release, Occurrence Occurrence &
Release
Include tag/ch in Subject
1
Off, On Off
1 You can set this when Alarm notification is not set to Off.
2 You can set this when the Detection is set to Channel.
3 You can set this when the Detection is set to Alarm level.
4 Release number 3 and later
Alarm notification
Set the recipients that will receive e-mails when alarms occur and are released.
Detection
Set the type for detecting alarm occurrence and release.
Channel set
Set the source channel for detecting alarm occurrence and release.
You cannot specify a channel of an AO module or PID control module.
Detection alarm 1 to 4
Set the alarm level for detecting alarm occurrence and release.
The setting applies to all channels.
Alarm notification mail is not sent when a control alarm occurs or is released.
Attach instantaneous data
Set this to On to include instantaneous data. The data that is attached is the instantaneous
value at the time an e-mail is transmitted.
Send alarm action
Set the type of alarm notification mail to transmit.
Include tag/ch in Subject
Set this to On to include the channel number and tag of the alarm detection channel in the
subject.
1.21ConfiguringtheEthernetCommunicationFunction