If you are recording display or event data in free run mode, the GX/GP start recording
when you start recording. If you are recording event data in trigger mode, the GX/GP
enters the trigger-wait state.
For the procedure to apply a record start trigger, see page 2-6 in section 2.1.3,
“Applying a Record Start Trigger for Event Data”.
For starting and stopping recording using event action, see page 1-162 in section 1.19,
“Configuring the Event Action Function”.
Stopping Recording
1
Press MENU.
The menu screen appears.
2
Tap Record.
The record stop screen appears.
3
Tap Rec+Math or Record.
Recording stops.
When computation (/MT option) is in progress, you can select Rec+Math. Computation
stops when recording stops.
On Models without the math function (/MT option), tap Stop.
4
Tap the Exit icon to close the menu screen.
Operation complete
You can also use the START/STOP key. If you use this key, recording will stop
immediately.
If START/STOP key action in the math channel settings is set to Start / Stop or Reset +
Start / Stop, computation also stops when you press the START/STOP key.
2.1.3 ApplyingaRecordStartTriggerforEventData
The procedure below can be carried out when recording event data in trigger mode and the
GX/GP is configured so that the start trigger is applied through trigger source operation.
In Recording settings, under Basic settings, event data Trigger source operation must
be set to On.
For details on the settings, see page 1-125 in section 1.12.1, “Setting the Type of Data to
Record (Display or event data) and Recording Conditions”.
Procedure
Triggering through Trigger Source Operation
Carry out the following procedure when the GX/GP is in the trigger-wait state.
1
Press MENU.
The menu screen appears.
2
Tap the Universal tab.
3
Tap Eventtrigger.
Recording starts.
When the measurement mode is set to Dual interval
A screen for selecting the measurement group that triggers will be applied to appears.
Tap the scan group that triggers will be applied to. To apply triggers to both scan
groups, tap ALL.
Operation complete
2.1 Starting and Stopping Recording and Computation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX20 and is the answer not in the manual?

YOKOGAWA GX20 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX20
CategoryRecording Equipment
LanguageEnglish

Related product manuals