1-202
IM 04L51B01-01EN
Register
Set the register number of the slave.
You can specify an input register in the range of 30001 to 39999 or 300001 to 365536. You
can specify a hold register in the range of 40001 to 49999 or 400001 to 465536.
The register numbers that you can specify vary depending on the type of command. See
page 4-11 in section 4.5, “Modbus Function and Register Assignments”.
Channel type
When the type is set to Read, only communication channels are available.
When the type is set to Write, set the channel type of the data to send.
First-CH, Last-CH
Set the first channel number and the last channel number in accordance with the channel
type.
1.22ConfiguringtheSerialCommunicationFunction(/C2and/C3options)