Configuring the GX/GP and Viewing the Settings
1
1.29 Initializing and Calibrating the System
(Initialization,reconfiguration,touchscreen
calibration),SettingtheMeasurementMode
Initialize the settings or the internal memory, reconfigure the GX/GP, and calibrate the touch
screen.
For details on A/D calibration, see page 5-6 in section 5.1.3, “Performing A/D Calibration
and Adjusting the Input Accuracy of AI Modules”.
For details on the advanced security settings (when the advanced security function (/
AS option) is in use), see section 2.1, “Enabling the Advanced Security Function,” in the
Advanced Security Function (/AS) User’s Manual (IM 04L51B01-05EN).
For details on encryption and certificates, see page 1-258 in section 1.30, “Configuring
Key Creation, Certificate Management, and Encryption/Certificate (SSL communication,
PDF electronic signature) (Release number 2 and later)”.
For details on updating the firmware (Web application, I/O module, and expansion
module), see page 5-21 in section 5.1.8, “Updating the Firmware (Release number 2 and
later)”.
For the multi batch settings (multi-batch function (/BT option)), see section 2.1.1, “Settings
for the Multi-batch Function,” in the Multi-batch Function (/BT) User’s Manual (IM 04L51B01-
03EN).
1.29.1 Initializing the Settings and the Internal Memory
Path
GX/GP: MENU key > Browse tab > Initialize Calibration > Menu Initialize > Settings/
Internal data
Description
Setup Item Selectable Range or Options Default Value
Initialize all Off, On Off
Initialize all
Set this to On to initialize all settings and return the GX/GP to its factory default condition.
However, the A/D calibration password is not initialized.
Setup Item Selectable Range or Options Default Value
Security settings
1
Off, On Off
Control settings
3
Off, On Off
Other
1
Off, On Off
Communication(IP address)
1, 2
Off, On Off
Communication(Server settings)
1, 2
Off, On Off
Calibration correction settings
1, 2
Off, On Off
Instruments tags, etc.
1, 2
Off, On Off
1 You can set this when Initialize all is set to Off.
2 You can set this when Other is set to On. Release number 4 and later.
3 You can set this when a PID control module is detected. Release number 4 and later.
Security settings
Set this to On to initialize the security settings.
Control settings
Set this to On to initialize control settings.
Setup items that are initialized
• Control settings
• Program pattern settings
• Control event action