STwrench User Guide Pset
9836 4134 01 Edition 2.9 105 (326)
6.7.1.2 Torque (Control) / Angle (Monitor)
This strategy guides the operator in reaching the desired target torque and monitoring the angle.
The Start Final Angle parameter is the threshold from which to start angle measurement (normally set to
50% of the Target Torque).
The green area defines the OK result area.
If the torque goes over the Change Screw value, a message is shown on the wrench display advising the
operator to replace the screw.
Torque/angle results:
- If the torque/angle does not exceed the torque/angle limits, the result is taken at the torque
peak or angle peak as specified in the Pset options.
- If the torque/angle goes over the limit, the result is taken as follows:
Cycle start
Torque peak selected in the Pset options
Angle peak selected in the Pset options