SV-DA200 series AC servo drive Function codes
-121-
P2.11
Speed feed-forward filter
time
Setting range
Default
Unit
Available mode
0.0064.00
0.50
ms
P
This parameter is used to set the speed feed-forward filter time.
P2.11
Data size
16bit
Data format
DEC
Modbus address
1422, 1423
CANopen address
0x220B, 0x00
P2.12
Torque feed-forward gain
Setting range
Default
Unit
Available mode
0.0100.0
0.0
%
P
S
This parameter is used to set the torque feed-forward gain. After the torque command calculated
according to speed control command multiplies the rate of the parameter, add to the torque
command from speed control step.
Increasing torque feed-forward gain can improve response performance in ACC/DEC and reduce
position deviation.
P2.12
Data size
16bit
Data format
DEC
Modbus address
1424, 1425
CANopen address
0x220C, 0x00
P2.13
Torque feed-forward filter
time
Setting range
Default
Unit
Available mode
0.0064.00
0.00
ms
P
S
This parameter is used to set the torque feed-forward filter time.
P2.13
Data size
16bit
Data format
DEC
Modbus address
1426, 1427
CANopen address
0x220D, 0x00
P2.14
1
st
IPPI coefficient
Setting range
Default
Unit
Available mode
01000
100
%
P
S
T
This parameter is used to set 1
st
IPPI coefficient.
Note: IP control will be applied when it is set to 0 and PI control will be applied when it is set to
100.
P2.14
Data size
16bit
Data format
DEC
Modbus address
1428, 1429
CANopen address
0x220E, 0x00
P2.15
2
nd
IPPI coefficient
Setting range
Default
Unit
Available mode
01000
100
%
P
S
T
This parameter is used to set 2
nd
IPPI coefficient.
Note: IP control will be applied when it is set to 0 and PI control will be applied when it is set to
100.
P2.15
Data size
16bit
Data format
DEC
Modbus address
1430, 1431
CANopen address
0x220F, 0x00

Table of Contents

Other manuals for INVT SV-DA200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT SV-DA200 Series and is the answer not in the manual?

INVT SV-DA200 Series Specifications

General IconGeneral
BrandINVT
ModelSV-DA200 Series
CategoryServo Drives
LanguageEnglish

Related product manuals