SV-DA200 series AC servo drive Control mode applications
-68-
When inductive loads such as relay coil are connected, a free wheel diode must be fitted as
shown in the figure; when optical coupler is connected, current limit resistor must be connected,
otherwise the drive will be damaged.
The local 24V power supply only can provide 100mA current. If the actual load current is larger
than 100mA, the user should provide the power supply by themselves. The recommended
capacity is greater than 500mA.
4.5.5 Wiring of frequency division output circuit of encoder feedback signal
Differential mode:
Phase A, B and Z all provide differential output and open-collector output signals.
For differential output signal, it is recommended to use AM26C32 or equivalent differential
receiving chip and be sure to fit a terminal matching resistor of about 220Ω.
For the phase A, B, Z signal of open-collector output, as the signal pulse width is very narrow,
the user shall use high speed optical coupler to receive this signal.
Both output circuits have no isolation.