SV-DA200 series AC servo drive Running and operation
-87-
Restore the factory parameter
Analog input 1 zero drift clear
Analog input 2 zero drift clear
Analog input 3 zero drift clear
Absolute value encoder clear
Note: The auxiliary functions can be operated only when servo is disabled, otherwise users cannot
enter the auxiliary function menu.
5.2.5.2 Operation flowchart of trial jogging
Press MODE key to switch to the auxiliary function mode. Press UP/DOWN key to the
menu, and press SET key to the jogging interface. The interface will display the current speed of the
motor. Press UP key, the motor will rotate to the setting speed anticlockwise and stops when
releasing the key. Press DOWN key, the motor will rotate to the setting speed clockwise and stops
when releasing the key.
MODE
SET
UP press down
UP release
DOWN press down
DOWN release
5.2.5.3 Operation flowchart of restoring the factory parameter
Press MODE key to switch to the auxiliary function mode. Press UP/DOWN key to the
menu, and press SET key to the interface. The interface will display . Press SET key to
restore to the factory values, it will display , after finishing, it will display . The
operation flowcharts for restoring default values and clearing analog input 1 zero drift, analog input 2
zero drift and analog input 3 zero drift are the same.