SV-DA200 series AC servo drive Function codes
-155-
P4.30 Setting value
Action
During deceleration
After stopping
[0]
Coast to stop
Keep the inertia operation state
1
Dynamic brake to stop
Keep the inertia operation state
2
Dynamic brake stop
Dynamic braking state
3
External dynamic brake acts
Dynamic braking state
Note:
1. When P4.30 is set to 1, the dynamic brake works when motor speed is higher than the value of
P3.58 and does not work otherwise. After motor stops, dynamic brake will stop working.
2. If the running speed of servo motor is faster than rated speed, do not use the dynamic brake. If
the running speed is high with large inertia load, please use the dynamic brake with caution. Do
not start the dynamic brake frequently; otherwise, damage may occur to the servo drive.
P4.30
Data size
16bit
Data format
DEC
Modbus address
1860, 1861
CANopen address
0x241E, 0x00
P4.31
Max. speed limit
Setting range
Default
Unit
Available mode
020000
5000
r/min
P
S
T
This parameter can be used to set the highest running speed of servo motor. If the absolute value
of the speed command is larger than the value of this parameter, the magnitude of the actual
speed setting will be limited by this parameter; the direction is the same with that of the original
speed command. This parameter is active in all modes.
Note: The default value of this parameter is related to the power level of the drive.
P4.31
Data size
16bit
Data format
DEC
Modbus address
1862, 1863
CANopen address
0x241F, 0x00
P4.32
Overspeed level
Setting range
Default
Unit
Available mode
020000
6000
r/min
P
S
T
This parameter is used to set the overspeed level of the servo motor. When the rotation speed of
the motor exceeds this setting speed, overspeed fault alarm will be reported.
Note: The default value of this parameter is related to the power level of the drive.
P4.32
Data size
16bit
Data format
DEC
Modbus address
1864, 1865
CANopen address
0x2420, 0x00
P4.33
Pulse range of position
deviation
Setting range
Default
Unit
Available mode
02
27
100000
reference unit
P
This parameter is used to set the alarm threshold for the position deviation (Er22-0). In position
mode, when the number of retention pulses exceeds this setting value, position error fault will be
alarmed. When P4.33=0, it means position error will not be detected.
P4.33
Data size
32bit
Data format
DEC
Modbus address
1866, 1867
CANopen address
0x2421, 0x00

Table of Contents

Other manuals for INVT SV-DA200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT SV-DA200 Series and is the answer not in the manual?

INVT SV-DA200 Series Specifications

General IconGeneral
BrandINVT
ModelSV-DA200 Series
CategoryServo Drives
LanguageEnglish

Related product manuals