SV-DA200 series AC servo drive Running and operation
-75-
5.1.1.2 Checking after powering-on
After switching on both of the control circuit and main circuit power supplies, if the power supply is OK,
the LED indicator will display 0 first and then display 8. If there is no fault alarm of the servo drive, the
LED on the front panel displays the current speed of the servo motor as default. The default
parameter can be set through parameter P0.15. If there is a fault of the servo drive, the LED displays
current alarm sign and flickers. Please fix the fault by referring to chapter 9.
5.1.1.3 Set the motor code
Before enabling operation, please set P0.00 according to the motor code on motor nameplate,
otherwise, the motor may operate abnormally or reversely and cause safety issues.
5.1.2 Trial jogging
Trial jogging can check whether the servo drive and the servo motor are intact and conduct
preliminary debugging of the system including the servo drive, servo motor and peripheral equipment.
Run the servo motor by JOG operation after ensuring that the wiring is correct and there is no fault
alarm and no abnormal running, See chapter 5.2.5 for detailed instructions. Before jog running,
ensure:
The motor isn’t in running state. If the motor is running, JOG operation is invalid;
The load inertia shouldn’t exceed 15 times of the motor inertia. Otherwise it may cause serious
mechanical vibration;
The jog speed can be set via parameter P0.05.
The accelerating/decelerating time during jogging can be set via parameters P0.54, P0.55 and
P0.56, P0.57.
5.1.3 Running at the position control mode
Simple connection:
DC
12~24V
PULSE+ 23
PULSE- 24
SIGN+ 32
SIGN- 33
FG
Upper
pulse
generator
Servo drive
CN1
SON 16
COM+ 2
Parameter
Function
Setting value
P0.03
1
Control mode selection
0
P0.22
1
Pulse number per motor
resolution
Set according to
the requirement
P0.23
1
Pulse input
Set according to
the requirement
P0.24
1
Reverse of pulse input
direction
0

Table of Contents

Other manuals for INVT SV-DA200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT SV-DA200 Series and is the answer not in the manual?

INVT SV-DA200 Series Specifications

General IconGeneral
BrandINVT
ModelSV-DA200 Series
CategoryServo Drives
LanguageEnglish

Related product manuals