SV-DA200 series AC servo drive Function codes
-159-
Z pulse offset of
frequency-division output
Set the Z pulse offset of frequency-division output. The max offset cannot exceed the single-turn
resolution of frequency-division output. It is valid only when P4.69=0 [normal frequency-division
output].
Frequency division molecular
of external linear encoder
This parameter is used to set the frequency division molecular of external linear encoder.
Frequency division denominator
of external linear encoder
This parameter is used to set the frequency division denominator of external linear encoder,
which corresponds to the linear encoder pulse number needed by one-circle rotation of motor.
Direction reversal of
external linear encoder
This parameter is used to set the direction reversal of external linear encoder feedback counting.
Use the counting value of the linear encoder directly
Use after the reversing of the counting value of the linear encoder
Large mixed deviation
setting
In the fully-closed loop control, set the tolerance (mixed deviation) between the user unit
(reference unit) corresponding to the encoder feedback position and user unit (reference unit)
corresponding to the linear encoder feedback position. If R0.05 exceeds the setting value, the
drive will report Er22-1.