SV-DA200 series AC servo drive Function codes
-156-
P4.34
1
Brake overload detection
selection
Setting range
Default
Unit
Available mode
02
0
-
P
S
T
This parameter is used to set the regenerative brake mode and overload protection mode.
Setting value
Regenerative brake and overload protection
[0]
Disabled (no regenerative brake)
1
Embedded
2
External
P4.34
1
Data size
16bit
Data format
DEC
Modbus address
1868, 1869
CANopen address
0x2422, 0x00
P4.35
Enable out-of-control
speed detection
Setting range
Default
Unit
Available mode
01
1
-
P
S
T
This parameter is used to enable or disable the detection on out-of-control speed.
Setting value
Function
0
Disabled
[1]
Enabled
P4.35
Data size
16bit
Data format
DEC
Modbus address
1870, 1871
CANopen address
0x2423, 0x00
P4.36
1
Undervoltage protection
of main power supply
Setting range
Default
Unit
Available mode
01
1
-
P
S
T
This parameter is used to set whether the drive will report main circuit undervoltage alarm when
undervoltage occurs to the main power supply.
Setting value
Protection
0
Do not display the undervoltage fault of the main circuit (Er13-1)
[1]
Display the undervoltage fault of the main circuit (Er13-1) and stop
P4.36
1
Data size
16bit
Data format
DEC
Modbus address
1872, 1873
CANopen address
0x2424, 0x00
P4.37
Undervoltage detection
time of main power supply
Setting range
Default
Unit
Available mode
702000
70
ms
P
S
T
This parameter is used to set the undervoltage detection time of the main power supply.
Note: The function is invalid if it is set to 2000.
P4.37
Data size
16bit
Data format
DEC
Modbus address
1874, 1875
CANopen address
0x2425, 0x00
P4.38
Motor overload rate
Setting range
Default
Unit
Available mode
0.0500.0
115.0
%
P
S
T
This parameter is used to set the overload rate of motor.
The default value is 115.0%. When increasing the value of this parameter, please take the motor
overload capacity into consideration.

Table of Contents

Other manuals for INVT SV-DA200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT SV-DA200 Series and is the answer not in the manual?

INVT SV-DA200 Series Specifications

General IconGeneral
BrandINVT
ModelSV-DA200 Series
CategoryServo Drives
LanguageEnglish

Related product manuals