SV-DA200 series AC servo drive Function codes
-156-
Brake overload detection
selection
This parameter is used to set the regenerative brake mode and overload protection mode.
Regenerative brake and overload protection
Disabled (no regenerative brake)
Enable out-of-control
speed detection
This parameter is used to enable or disable the detection on out-of-control speed.
Undervoltage protection
of main power supply
This parameter is used to set whether the drive will report main circuit undervoltage alarm when
undervoltage occurs to the main power supply.
Do not display the undervoltage fault of the main circuit (Er13-1)
Display the undervoltage fault of the main circuit (Er13-1) and stop
Undervoltage detection
time of main power supply
This parameter is used to set the undervoltage detection time of the main power supply.
Note: The function is invalid if it is set to 2000.
This parameter is used to set the overload rate of motor.
The default value is 115.0%. When increasing the value of this parameter, please take the motor
overload capacity into consideration.