Changing the Set Values of the Heaters
Reference for Temperature Setting
Changing the Temperature Settings for the Heaters
Here, each item of "SET TEMP." and "SET TIME" is set.
1
Press the key in LOCAL to select the
printing mode.
2
Press the key.
3
Press the key.
4
Press to select one of the types (1 to 4) and press the key.
Ink type
ES3 ink SS21 ink
Media type
Glossy chloroethylene Tarpaulin FF All media
Pre-heater setting
40°C 40°C 40°C 35°C
Print heater setting
40°C 40°C 40°C 35°C
Post-heater setting
50°C 50°C 50°C 50°C
• Adjust the temperature appropriately according to the state of the medium you use.
Temperature setting (SET TEMP.)
Used to change the set temperature of the pre-heater, print heater, and
post-heater inside the platen.
Time setting
*1
(SET TIME)
*1. The time set here is valid only when the printing is completed. The value when print & cut operation or cutting operation is
completed is deferent depending on the application software (RasterLinkPro4 or later, FineCut7 or later) you use.
STANDBY
Used to set the time it takes until the temperature of the heaters falls to
reach the preheat temperature after printing has been complete.
Set value:NONE, 0 to 90 min (by the unit of 10 min)
• The preheat temperature has been preset and cannot be changed.
• If the machine receives data with the preheat temperature reached, the
heaters automatically raise their temperature up to the set temperature, and
then the machine starts printing.
• When the set value has been set to "NONE", the heaters do not lower their
temperature to the preheat one.
OFF TIME
The heaters are turned off in the following cases:
• When printing is not performed longer than the preset time in the standby
mode
• When printing is not performed longer than the preset time after printing has
been completed with "NONE" being selected for the set value of
"STANDBY"
Set value:NONE, 0 to 90 min (by the unit of 10 min)
If the machine receives data with the heaters turned off, the heaters are
automatically turned on to raise their temperatures up to the preset levels
and then the machine starts printing.
• When "NONE" is selected for the set value, the heaters are not turned off.
• When "0 min" is set for the set value, the heaters are turned off after printing
has been complete.
<LOCAL . 1> [ #01 ]
WIDTH:****mm
FUNCT I ON
SETUP <ENT>
SETUP
SELECT : TYPE . 1

Table of Contents

Other manuals for MIMAKI JV5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV5 Series and is the answer not in the manual?

MIMAKI JV5 Series Specifications

General IconGeneral
BrandMIMAKI
ModelJV5 Series
CategoryPrinter
LanguageEnglish

Related product manuals