874 Configuring Connectivity Fault Management
Configuring MEP Information
Beginning in Privileged Exec mode, use the following commands to configure
the mode and view related settings.
CLI Command Description
configure Enter global configuration mode.
interface
interface
Enter Interface Config mode for the specified
interface, where
interface
is replaced by
gigabitethernet
unit/slot/port
, or tengigabitethernet
unit/slot/port
.
ethernet cfm mep enable level
level
vlan
vlan-id
mpid
mep-id
Define the port as a maintenance endpoint (MEP)
and associate it with an SVLAN in a domain. When
the MEP is enabled, it will generate CCM messages.
ethernet cfm mep level
level
direction {up | down} mpid
mep-id
vlan
vlan-id
Enable a MEP at the specified level and direction.
ethernet cfm mep active Set the administrative state of the MEP to active.
ethernet cfm mip level
level
Create a MIP at the specified level on the interface.
exit Exit to privileged Exec Mode
show ethernet cfm
maintenance–points
Add the keywords local domain, local interface,
local level, remote domain, or remote level to show
information on local or remote endpoints.
show ethernet cfm statistics Display statistics per MEP.

Table of Contents

Other manuals for Dell N3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell N3000 Series and is the answer not in the manual?

Dell N3000 Series Specifications

General IconGeneral
ManagedYes
Stacking Ports2 x 10GbE SFP+
Weight12.3 lbs (5.6 kg)
Operating Temperature32° to 113°F (0° to 45°C)
Ports24 or 48 10/100/1000 ports

Related product manuals