Before starting with the installation
I
l
Installation requires qualified electrician
l
Disconnect the power supply of the device.
l
Secure against retriggering
l
Verify isolation from the supply
l
Ground and short-circuit
l
Cover or enclose any
neighboring live parts.
l
Follow the engineering instructions (IL) of the
device concerned.
l
Only suitably qualified personnel in accordance
with EN 50110-1/-2 (VDE 0105 part 100) may work on
this device/system.
l
Before installation and before touching the device
ensure that you are free of electrostatic charge.
l
The functional earth (FE) must be connected to the
protective earth (PE) or to the equipotential bond-
ing. The system installer is responsible for imple-
menting this connection.
l
Connecting cables and signal lines should be
installed so that inductive or capacitive inter-
ference does not impair the automation functions.
l
Install automation devices and related operating
elements in such a way that they are well protected
against unintentional operation.
l
Suitable safety hardware and software measures
should be implemented for the I/O interface so that
a line or wire breakage on the signal side does not
result in undefined states in the automation
devices.
l
Deviations of the mains voltage from the nominal
value must not exceed the tolerance limits given in
the specifications, otherwise this may result in mal-
function and hazardous states.
l
Emergency-Stop devices complying with IEC/EN
60204-1 must be effective in all operating modes of
the automation devices. Unlatching the emergency
switching off devices must not result in an auto-
matic restart.
l
Built-in devices for enclosures or cabinets must
only be run and operated in an installed state;
desktop devices and portable devices only when
the housing is closed.
l
Measures should be taken to ensure the proper
restarting of programs interrupted after a voltage
dip or outage. This should not result in dangerous
operating states even for a short time. If necessary,
emergency switching off devices should be imple-
mented.
l
Wherever faults in the automation system may
cause damage to persons or property, external
measures must be implemented to ensure a safe
operating state in the event of a fault or malfunction
(for example, by means of separate limit switches,
mechanical interlocks, etc.).
DANGER!
Hazardous electrical voltage!

Table of Contents

Other manuals for Eaton easyE4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton easyE4 and is the answer not in the manual?

Eaton easyE4 Specifications

General IconGeneral
BrandEaton
ModeleasyE4
CategoryRelays
LanguageEnglish