MAINTENANCE
7-55
Change Engine Oil
--- every 500 hours
Replace Engine Oil Filter
--- every 500 hours
d
CAUTION: Engine oil may be hot just after operation.
Take extra care to avoid burns.
After refilling, make sure oil filler cap (2) is securely
closed.
1. Run the engine to warm oil.
DO NOT run the engine until oil is hot.
2. Park the machine on a firm, level surface.
3. Lower the bucket to the ground.
4. Turn the auto-idle switch off.
IMPORTANT: The turbocharger may be damaged if the
engine is not properly shut down.
5. Run the engine at slow idle speed without load for 5
minutes.
6. Turn the key switch OFF. Remove the key from the key
switch.
7. Pull the pilot control shut-off lever to the LOCK position.
2
MDAT-07-011
ZX135US-6