EasyManuals Logo
Home>Hitachi>Excavators>ZAXIS 135US-6 class

Hitachi ZAXIS 135US-6 class User Manual

Hitachi ZAXIS 135US-6 class
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #461 background imageLoading...
Page #461 background image
MAINTENANCE
7-169
Replace DEF/AdBlue® Supply Module Main Filter
--- every 4500 hours
A filter (4) is mounted in the DEF/AdBlue® pump. Periodically
replace filter (4).
d
CAUTION: Wear safety equipment such as safety
glasses or goggles, rubber gloves appropriate to
the job. Wash DEF/AdBlue® with clean water when it
contacts with the skin. If DEF/AdBlue® is accidentally
splashed into eyes, flush with water for 15 minutes or
longer and get emergency medical attention.
IMPORTANT:
Take care not to allow dirt and/or water to enter the
DEF/AdBlue® tank while replacing filter (4).
Check for leaks around the mounting position after
replacement.
White deposition may be observed when DEF/
AdBlue® is dried naturally; it is normal. Wash out
DEF/AdBlue® deposition with clean water. Never use
a high pressure washer.
1. Park the machine according to the instruction on
Preparations for Inspection and Maintenance (7-8).
4
MLAD-07-037

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 135US-6 class and is the answer not in the manual?

Hitachi ZAXIS 135US-6 class Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 135US-6 class
CategoryExcavators
LanguageEnglish

Related product manuals