Operation Manual – GVRP
Quidway S3100 Series Ethernet Switches Chapter 1
GVRP Configuration
Huawei Technologies Proprietary
1-4
Field Description Value
Attribute Event
The event described by the
attribute
0: LeaveAll Event
1: JoinEmpty
2: JoinIn
3: LeaveEmpty
4: LeaveIn
5: Empty
Attribute Value The value of the attribute
The attribute value of GVRP
is the VID.
End Mark End mark of the GVRP PDU. —
1.1.3 Protocol Specifications
GVRP is defined in IEEE 802.1Q standard.
1.2 GVRP Configuration
The GVRP configuration tasks include configuring the timers, enabling GVRP, and
configuring the GVRP port registration mode.
1.2.1 Configuration Prerequisite
The port on which GVRP will be enabled must be set to a Trunk port.
1.2.2 Configuration Procedure
Table 1-2 Configuration procedure
Operation Command Description
Enter system
view
system-view
—
Configure the
LeaveAll timer
garp timer leaveall
timer-value
Optional
By default, the LeaveAll timer is
set to 1,000 centiseconds.
Enter Ethernet
port view
interface interface-type
interface-number
—
Configure the
Hold, Join, and
Leave timers
garp timer { hold | join |
leave } timer-value
Optional
By default, the Hold, Join, and
Leave timers are set to 10, 20,
and 60 centiseconds
respectively.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3100 Series and is the answer not in the manual?

Huawei Quidway S3100 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3100 Series
CategorySwitch
LanguageEnglish

Related product manuals