Operation Manual – QoS
Quidway S3100 Series Ethernet Switches Chapter 1
QoS Configuration
Huawei Technologies Proprietary
1-13
Operation Command Description
Enter Ethernet port
view of the
monitoring port
interface interface-type
interface-number
—
Set the port as
monitoring port
monitor-port
Required
Exit from the
current view
quit
—
Enter Ethernet port
view of the
monitored port
interface interface-type
interface-number
—
Set the port as
monitored port
mirroring-port { inbound |
outbound | both }
Required
inbound: Only monitors
inbound packets of the port.
outbound: Only monitors
outbound packets of the port.
both: Monitors both inbound
and outbound packets of the
port.
Display local port
monitoring settings
display mirroring-group
local
Can be executed in any view.
1.8.3 Configuration Example
I. Network requirements
z To monitor and analyze inbound and outbound packets of ports connected to
Ethernet1/0/2 via monitoring devices.
z The monitoring devices are attached to Ethernet1/0/1.
Configure as follows:
z Set Ethernet1/0/2 as the monitored port. Set to monitor both its inbound and
outbound packets.
z Set Ethernet1/0/1 as the monitoring port.
II. Configuration procedure
<Quidway> system-view
[Quidway] interface ethernet1/0/1
System View: return to User View with Ctrl+Z.
[Quidway-Ethernet1/0/1] monitor-port
[Quidway-Ethernet1/0/1] quit
[Quidway] interface ethernet1/0/2
[Quidway-Ethernet1/0/2] mirroring-port both
[Quidway-Ethernet1/0/2] display mirroring-group local