Operation Manual – Information Center
Quidway S3100 Series Ethernet Switches Chapter 1
Information Cente
Huawei Technologies Proprietary
1-10
1.2.5 Enabling Information Output to the Log Buffer
Table 1-10 lists the related configurations on the switch.
Table 1-10 Enable information output to the log buffer
Operation Command Description
Enter system view
system-view
—
Enable the
information center
info-center enable
Optional
By default, the information
center is enabled.
Enable information
output to the log
buffer
info-center logbuffer
[ channel { channel-number
| channel-name } | size
buffersize ]
Optional
By default, the switch outputs
information to the log buffer,
which can holds up to 512
items by default.
Define an
information source
info-center source
{ modu-name | default }
channel { channel-number |
channel-name } [ { log | trap
| debug } * { level severity |
state state } * ]
Required
Set the format of
time stamp
info-center timestamp
{ log | trap | debugging }
{ boot | date | none }
Optional
This is to set the time stamp
format for log/debug/trap
information output.
This determines how the time
stamp is presented to users.
 Note:
To view debug information of specific modules, you need to set the information type as
debug in the info-center source command, and enable debugging on corresponding
modules with the debugging command as well.