Operation Manual – Information Center
Quidway S3100 Series Ethernet Switches Chapter 1
Information Cente
Huawei Technologies Proprietary
1-4
Module name Module and description
XM Xmodem
default Default settings of all the modules
Note that a slash (/) separates the module name and severity level.
5) Level
Switch information falls into three categories: log information, debug information and
trap information. Information of each category can be one of eight severities.
Information filtering prevents information whose severity is lower than the specified
threshold from being output. The higher the information severity is, the lower the
corresponding level is. For example, the “debugging” severity corresponds to level 8,
and the “emergencies“ severity corresponds to level 1. When the severity threshold is
set to “debugging”, all information will be output. See
Table 1-2 for description of
severities and corresponding levels.
Table 1-2 Severity definitions on the information center
Severity Value Description
emergencies 1 The system is unavailable.
alerts 2 Errors that need to be corrected immediately
critical 3 Critical errors
errors 4 Common errors
warnings 5 Warnings
notifications 6 Normal information that needs to be noticed
informational 7 Normal prompt information
debugging 8 Debug information
Note that a slash (/) separates the level and digest.
6) Digest
It is a phrase within 32 characters, abstracting the information contents.
A colon (:) separates the digest and information contents.
1.2 Information Center Configuration
The switch supports information output to six directions.
By far, each output direction is assigned with an information channel, as shown in
Table
1-3
.