2. Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command:
user@switch> show chassis fabric summary
Plane State Uptime
0 Online 2 days, 19 hours, 10 minutes, 9 seconds
1 Online 2 days, 19 hours, 10 minutes, 9 seconds
...
3. Verify that the backup Roung Engine is back online by issuing the show chassis routing-engine 1
command:
user@switch> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Backup
...
4. Verify that the EX9200-SF3s appear in output from the show chassis hardware command:
user@switch> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1221A03RFC EX9204
Midplane REV 01 750-053633 ACRA1451 EX9204-BP
FPM Board REV 04 760-021392 ABCB4822 Front Panel Display
PEM 0 Rev 10 740-029970 QCS1251U020 PS 1.4-2.52kW; 90-264V AC in
PEM 1 Rev 10 740-029970 QCS1251U028 PS 1.4-2.52kW; 90-264V AC in
Routing Engine 0 REV 02 740-049603 9009153805 RE-S-EX9200-1800X4
Routing Engine 1 REV 02 740-049603 9009153993 RE-S-EX9200-1800X4
CB 0 REV 08 750-048307 CABC6474 EX9200-SF3
CB 1 REV 10 750-048307 CABH8948 EX9200-SF3
...
Removing an SF Module from an EX9200 Switch
Before you begin to remove an SF module:
• Ensure you understand how to prevent electrostac discharge (ESD) damage. See
Prevenon of
Electrostac Discharge Damage
.
236