Parameter Name / value range / [default seng] Info
0x2000:016
(P190.16)
Device data: Bootloader revision number
(Device data: Bootloader revNo)
Read only
Bootloader version of the network opon.
0x2001
(P191.00)
Device name
(Device name)
["My Device"]
Any device name (e.g. "Wheel drive") can be set in this object for the
purpose of device idencaon.
0x2002:004
(P192.04)
Device module: CU type code
(Device module: CU type code)
Read only
Type code of the control unit.
0x2002:005
(P192.05)
Device module: PU type code
(Device module: PU type code)
Read only
Type code of the power unit.
0x2002:006
(P192.06)
Device module: CU serial number
(Device module: CU serial number)
Read only
Serial number of the control unit.
0x2002:007
(P192.07)
Device module: PU serial number
(Device module: PU serial number)
Read only
Serial number of the power unit.
6.2.11 Device overload monitoring (i*t)
The inverter calculates the i*t ulisaon in order to protect itself against thermal overload. In
simple terms: a higher current or an overcurrent that connues for a longer me causes a
higher i*t ulisaon.
DANGER!
Uncontrolled motor movements by pulse inhibit.
When the device overload monitoring funcon is acvated, pulse inhibit is set and the motor
becomes torqueless. A load that is connected to motors without a holding brake may there-
fore cause uncontrolled movements! Without a load, the motor will coast.
Only operate the inverter under permissible load condions.
Details
The device overload monitoring funcon primarily oers protecon to the power secon.
Indirectly, also other components such as lter chokes, circuit-board conductors, and termi-
nals are protected against overheang. Short-me overload currents followed by recovery
periods (mes of smaller current ulisaon) are permissible. The monitoring funcon during
operaon checks whether these condions are met, taking into consideraon that higher
switching frequencies and lower stator frequencies as well as higher DC voltages cause a
greater device ulisaon.
If the device ulisaon exceeds the warning threshold set in 0x2D40:002 (default seng:
95 %), the inverter outputs a warning.
If the device ulisaon exceeds the permanent error threshold 100 %, the inverter is disa-
bled immediately and any further operaon is stopped.
Device overload monitoring depends on the inverter load characterisc 0x2D43:001
(P306.01).
The device overload can be obtained from the conguraon document.
Parameter Name / value range / [default seng] Info
0x2D40:002 Device ulisaon (i*t): Warning threshold
0 ... [95] ... 101 %
If the device ulisaon exceeds the threshold set, the inverter outputs a
warning.
With the seng 0 % or ≥ 100 %, the warning is deacvated.
0x2D40:004
(P135.04)
Device ulisaon (i*t)
(Device ulisat.: ixt ulisaon)
Read only: x %
Display of the current device ulisaon.
Diagnoscs and fault eliminaon
Diagnoscs parameter
Device idencaon
136

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals