Parameter Name / value range / [default seng] Info
0x2000:016
(P190.16)
Device data: Bootloader revision number
(Device data: Bootloader revNo)
•
Read only
Bootloader version of the network opon.
0x2001
(P191.00)
Device name
(Device name)
["My Device"]
Any device name (e.g. "Wheel drive") can be set in this object for the
purpose of device idencaon.
0x2002:004
(P192.04)
Device module: CU type code
(Device module: CU type code)
•
Read only
Type code of the control unit.
0x2002:005
(P192.05)
Device module: PU type code
(Device module: PU type code)
•
Read only
Type code of the power unit.
0x2002:006
(P192.06)
Device module: CU serial number
(Device module: CU serial number)
•
Read only
Serial number of the control unit.
0x2002:007
(P192.07)
Device module: PU serial number
(Device module: PU serial number)
•
Read only
Serial number of the power unit.
6.2.11 Device overload monitoring (i*t)
The inverter calculates the i*t ulisaon in order to protect itself against thermal overload. In
simple terms: a higher current or an overcurrent that connues for a longer me causes a
higher i*t ulisaon.
DANGER!
Uncontrolled motor movements by pulse inhibit.
When the device overload monitoring funcon is acvated, pulse inhibit is set and the motor
becomes torqueless. A load that is connected to motors without a holding brake may there-
fore cause uncontrolled movements! Without a load, the motor will coast.
▶
Only operate the inverter under permissible load condions.
Details
The device overload monitoring funcon primarily oers protecon to the power secon.
Indirectly, also other components such as lter chokes, circuit-board conductors, and termi-
nals are protected against overheang. Short-me overload currents followed by recovery
periods (mes of smaller current ulisaon) are permissible. The monitoring funcon during
operaon checks whether these condions are met, taking into consideraon that higher
switching frequencies and lower stator frequencies as well as higher DC voltages cause a
greater device ulisaon.
•
If the device ulisaon exceeds the warning threshold set in 0x2D40:002 (default seng:
95 %), the inverter outputs a warning.
•
If the device ulisaon exceeds the permanent error threshold 100 %, the inverter is disa-
bled immediately and any further operaon is stopped.
•
Device overload monitoring depends on the inverter load characterisc 0x2D43:001
(P306.01).
•
The device overload can be obtained from the conguraon document.
Parameter Name / value range / [default seng] Info
0x2D40:002 Device ulisaon (i*t): Warning threshold
0 ... [95] ... 101 %
If the device ulisaon exceeds the threshold set, the inverter outputs a
warning.
•
With the seng 0 % or ≥ 100 %, the warning is deacvated.
0x2D40:004
(P135.04)
Device ulisaon (i*t)
(Device ulisat.: ixt ulisaon)
•
Read only: x %
Display of the current device ulisaon.
Diagnoscs and fault eliminaon
Diagnoscs parameter
Device idencaon
136