EasyManuals Logo

Lenze i55AE155F User Manual

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background image
8.3.3 Opmising the stalling behaviour
If the motor is driven with frequencies above the rated motor frequency, the operang point
is shied to the "eld weakening range". In this range, the motor voltage does not increase
proporonately to the output frequency anymore. As a consequence, the inverter automa-
cally reduces the maximum current since the full torque is not available anymore at these fre-
quencies.
For special motors which enable an operaon in the eld weakening range, the behaviour in
the eld weakening range can be adapted to the motor with 0x2B0C (P319.00).
DANGER!
Danger by incorrect parameterisaon.
Possible consequences: damage to material assets and injury to persons
Only change the default seng (0 Hz) in 0x2B0C (P319.00) aer consulng the motor man-
ufacturer!
Recommendaon: Maintain default seng (0 Hz).
Precondions
The funcon is only eecve in the following motor control types:
V/f characterisc control (VFC open loop)
V/f characterisc control (VFC closed loop)
Motor control
Opmisaon of motor control
Opmising the stalling behaviour
186

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals