9.11.4 Diagnoscs
The controlled node indicates applied diagnosc data by an emergency message to the man-
aging node.
Details
The XXXX parameter serves to suppress the transmission of emergency messages to the
managing node. Thus, errors of a certain type can be suppressed in a targeted way.
Errors and warnings of the inverter and the network opon are sent as extended diagnos-
c messages to the managing node:
Bytes Meaning Value [hex]
1 ... 6 Diagnosc block header 0x0010 001C 0100
7 ... 8 Alarm type 0x0001 (diagnoscs)
9 ... 12 API (Applicaon Programming Interface) 0x0000 0000
13, 14 Slot number 0x0001 / 0x0002
15, 16 Subslot number 0x0001
17 ... 20 Module ID ID according to module
21 ... 24 Submodule number ID according to module
25, 26 Alarm specicaon 0xB000
27, 28 User structure ID 0x0001
29 ... 32 Error code
4Error codes ^ 639
9.11.5 Process data transfer
POWERLINK transfers process data, parameter data, conguraon data and diagnosc data
between the managing node and the involved controlled nodes. Depending on their me-crit-
ical behaviour, the data is transmied via corresponding communicaon channels.
Details
Process data is transmied cyclically between the managing node and the controlled node
(permanent exchange of current input and output data).
The transfer of process data is me-crical.
The process data serves to control the POWERLINK nodes.
The process data can be directly accessed by the managin node. The data in the PLC, for
instance, are directly stored in the I/O area.
The contents of the process data are dened via I/O data mapping.
Process data are not saved in the device.
Process data (RxPDO):
0x4008:001 (P590.01) (NetWordIN1)
0x400B:013 (P592.13) (Network frequency setpoint [+/-16384])
Process data (TxPDO):
0x400A:001 (P591.01) (NetWordOUT1)
0x400C:009 (P593.09) (Frequency [+/-16384])
0x2D88 (P104.00) (Motor current)
0x4050:002 (internal parameters)
Conguring the network
POWERLINK
Process data transfer
399

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals