9.4.14 Restart communicaon
The following parameter can be used to restart or stop communicaon. Oponally it is also
possible to reset all communicaon parameters to the default status.
Details
A restart of communicaon is required aer changes of the interface conguraon (e. g. node
address and baud rate) in order that the changed sengs become eecve.
For restarng communicaon, there are two opons:
a)
Switch inverter o and on again.
b)
Set the selecon = "Restart with current values [1]" in 0x2300 (P508.00).
Parameter Name / value range / [default seng] Info
0x2300
(P508.00)
CANopen communicaon
(CANopen comm.)
•
Seng can only be changed if the inverter is inhibi-
ted.
Restart / stop communicaon.
•
Aer successful execuon, the value 0 is shown.
0 No acon/no error Only status feedback
1 Restart with current values Restart communicaon with the current values.
2 Restart with default values Restart communicaon with the standard values of the CAN parameters
(0x1000 ... 0x1FFF and 0x2301).
5 Stop network communicaon Stop communicaon.
•
The "Stop Remote Node" NMT command is executed. Aer successful
execuon of this command, only the recepon of network manage-
ment frames is possible.
10 In progress Only status feedback
11 Acon cancelled
12 Error
Conguring the network
CANopen
Restart communicaon
278