9.8.5 Diagnoscs
The parameters for diagnosing the network are described below.
Parameter Name / value range / [default seng] Info
0x23B2:001
(P511.01)
Acve Modbus TCP sengs: Acve IP address
(Act. MBTCP se.: Act. IP address)
•
Read only
•
From version 04.00
Display of the acve IP address.
0x23B2:002
(P511.02)
Acve Modbus TCP sengs: Acve subnet
(Act. MBTCP se.: Act. subnet)
•
Read only
•
From version 04.00
Display of the acve subnet mask.
0x23B2:003
(P511.03)
Acve Modbus TCP sengs: Acve gateway
(Act. MBTCP se.: Act. gateway)
•
Read only
•
From version 04.00
Display of the acve gateway address.
Example
The seng 276344004 corresponds to the gateway address
196.172.120.16.
•
276344004 = 0x1078ACC4 à 0xC4.0xAC.0x78.0x10 = 196.172.120.16
0x23B2:005
(P511.05)
Acve Modbus TCP sengs: MAC address
(Act. MBTCP se.: MAC address)
•
Read only
•
From version 04.00
Display of the acve MAC address.
0x23B3
(P509.00)
Switch posion
(Switch posion)
•
Read only
•
From version 04.00
Display of the rotary encoder switch seng at the last mains power-on.
0x23B5:001
(P513.01)
Acve port sengs: Port 1
(Act. port se.: Port 1)
•
Read only
•
From version 04.00
Display of the baud rate set for the port 1 in parameter 0x23B4:001
(P512.01).
0 Not connected
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
0x23B5:002
(P513.02)
Acve port sengs: Port 2
(Act. port se.: Port 2)
•
Read only
•
From version 04.00
Display of the baud rate set for the port 2 in parameter 0x23B4:002
(P512.02).
0 Not connected
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
0x23B8
(P516.00)
Modbus TCP module status
(MBTCP modul. stat)
•
Read only
•
From version 04.00
Display of the TCP module state.
0 Power o
1 Inializaon
2 Warning
3 Fault
4 No conguraon
5 Operaonal
Conguring the network
Modbus TCP
Diagnoscs
353