5.3.4 Funcon assignment of the inputs and outputs
The inverter control can be adapted individually to the respecve applicaon. This is basically
eected by assigning digital control sources ("triggers") to funcons of the inverter.
By default, the inverter can be controlled via the I/O terminals as follows:
t
t
t
t
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
-40 Hz
-60 Hz
-50 Hz
-30 Hz
-20 Hz
-10 Hz
t
t
t
t
t
t
t
0x2DDD (P100.00)
Digital output 2 only available with Application I/O.
Braking function is switched off in default setting of 0x2820:001.
Digital output 2Error active [56]
Presets 1 ... 3Preset 1
RelayReady for operat. [51]
Digital output 1Release brake [115]
Output signals
OutputStatus signals
Output frequency
Activate preset (bit 1)
Activate preset (bit 0)
Invert rotation
Reset error
Run
Digital input 5 [15]
Digital input 4 [14]
Digital input 3 [13]
Digital input 2 [12]
Digital input 1 [11]
Input signals
Frequency setpoint selection
via analog input 1
Mains voltage
Fault status
FunctionTrigger
Parameter Name Default seng
Control funcons
①
0x2631:002 (P400.02) Run Digital input 1 [11]
②
0x2631:004 (P400.04) Reset fault Digital input 2 [12]
③
0x2631:013 (P400.13) Reverse rotaonal direcon Digital input 3 [13]
④
0x2631:018 (P400.18) Acvate preset (bit 0) Digital input 4 [14]
⑤
0x2631:019 (P400.19) Acvate preset (bit 1) Digital input 5 [15]
Conguraon of digital outputs
⑥
0x2634:001 (P420.01) Relay Ready for operaon [51]
⑦
0x2634:002 (P420.02) Digital output 1 Release holding brake [115]
⑧
0x2634:003 (P420.03) Digital output 2 (only for applicaon I/O) Error acve [56]
Sengs for the frequency setpoint
⑨
0x2860:001 (P201.01) Frequency control: Default setpoint source Analog input 1 [2]
⑩
0x2911:001 (P450.01) Frequency setpoint presets: Preset 1 20 Hz
⑪
0x2911:002 (P450.02) Frequency setpoint presets: Preset 2 40 Hz
⑫
0x2911:003 (P450.03) Frequency setpoint presets: Preset 3 50 Hz
⑬
0x2917 (P220.00) Acceleraon me 1 5.0 s
⑭
0x2918 (P221.00) Deceleraon me 1 5.0 s
Commissioning
Parameter seng
Funcon assignment of the inputs and outputs
82