EasyManuals Logo
Home>Lenze>Inverter>i55AE155F

Lenze i55AE155F User Manual

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #622 background imageLoading...
Page #622 background image
15 Technical data
15.1 Standards and operang condions
15.1.1 Conformies/approvals
Conformity
CE 2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC TR TC 004/2011 Eurasian conformity: safety of low voltage equipment
TP TC 020/2011 Eurasian conformity: electromagnec compability of technical
means
RoHS 2 2011/65/EU Restricons for the use of specic hazardous materials in electric
and electronic devices
Approval
UL UL 61800-5-1 for USA and Canada (requirements of the CSA 22.2 No. 274)
File No. E132659
15.1.2 Protecon of persons and device protecon
Enclosure
IP20 EN 60529
Type 1 NEMA 250 Protecon against contact
Open type only in UL-approved systems
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m a.m.s.l.
Overvoltage category II above 2000 m a.m.s.l.
Control circuit isolaon
Safe mains isolaon by double/reinforced
insulaon
EN 61800-5-1
Protecve measures against
Short circuit
earth fault Earth fault strength depends on the operang status
Overvoltage
Motor stalling
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Observe regulaons and safety instrucons!
Starng current
≤ 3 x rated mains current
15.1.3 EMC data
Actuaon on public supply systems
Implement measures to limit the radio interfer-
ence to be expected:
The machine or plant manufacturer is responsible for compliance
with the requirements for the machine/plant!
< 1 kW: with mains choke EN 61000-3-2
> 1 kW at mains current ≤ 16 A: without addi-
onal measures
Mains current > 16 A: with mains choke or
mains lter, with dimensioning for rated
power. Rsce ≥ 120 is to be met.
EN 61000-3-12 RSCE: short-circuit power rao at the connecon point of the
machine/plant to the public network.
Noise emission
Category C1 EN 61800-3 Type-dependent, for motor cable lengths see rated data
Category C2
Noise immunity
Meets requirement in compliance with EN 61800-3
Technical data
EMC data
622

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals