14.1 Control source change-over
The term "control sources" in this connecon refers to the digital signal sources from which
the inverter receives its start, stop, and reversal commands.
Possible control sources are:
•
Digital inputs
•
Keypad
•
Network
Details
First, select in 0x2824 (P200.00) whether the start of the motor is to be congured exibly
(default seng) or exclusively via the keypad. 4Control source selecon ^ 147
If "Flexible I/O conguraon" is set, a change-over from one control source to another can be
eected during operaon via the funcons listed in the following table. The inverter not only
supports such a change-over via its digital inputs, but also as a funcon of internal inverter
states.
Acvate keypad control
0x2631:012 (P400.12)
Acvate network control
0x2631:037 (P400.37)
Acve control source
FALSE / Not connected FALSE / Not connected
Flexible I/O conguraon (default seng)
•
The motor is controlled via the digital inputs.
•
For precongured assignment of the digital inputs, see chapter "Func-
on assignment of the inputs and outputs". ^ 82
•
For descripon of the basic funcons for controlling the motor, see
chapter "Start / stop motor". ^ 531
FALSE / Not connected TRUE
Network
•
Starng the motor is only possible via the network control word.
•
Excepon: Jog operaon; see chapter "Start / stop motor". ^ 531
4Example 2: Change-over from terminal control to network control
^ 530
TRUE Any
Keypad
•
Starng the motor is only possible via the keypad key.
•
Excepon: Jog operaon; see chapter "Start / stop motor". ^ 531
4Example 1: Change-over from terminal control to keypad control ^ 529
The following signal ow shows the internal control logics:
1
0
0x2631 037:
1
0
0x2631 012:
1
0
0x2824
0x2838 001:
0x2838 003:
0x282B 001:
0x2631 003:
0x2631:001
0x2631 002:
0x2631 006:
0x2631 007:
0x2631 008:
0x2631 009:
0x2631 010:
0x2631 011:
1
0
1
Run reverse (CCW)
Jog operation
Stop
Stop ("KSTOP")
0: Flexible I/O configuration
1: Network
2: Keypad
0: Flexible I/O configuration
1: Keypad
Control selection Active control source
Motor control
Stop method
Start method
Start/Stop
Quick stop
Disable inverter
Run
Stop
Keypad
Run forward (CW)
Network
Start reverse (CCW)
Start forward (CW)
Run forward (CW)
Activate quick stop
Enable inverter
Activate keypad control
Activate network control
Jog foward (CW)
Run reverse (CCW)
Jog reverse (CCW)
Run
Flexible I/O configuration
Flexible I/O conguraon
Control source change-over