EasyManuals Logo
Home>Lenze>Inverter>i55AE155F

Lenze i55AE155F User Manual

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #563 background imageLoading...
Page #563 background image
14.3.7 Setpoint source segment setpoints
The four funcons "Acvate segment setpoint (bit 0)" ... " Acvate segment setpoint´(bit 3)"
enable a setpoint change-over to a segment setpoint parameterised for the "sequencer" func-
on during normal operaon.
Precondions
A setpoint change-over to the respecve segment setpoint is only eected if no setpoint
source with a higher priority has been selected. 4Priority of the setpoint sources ^ 548
Details
A segment setpoint is selected in a binary-coded fashion via the triggers assigned to the four
funcons "Acvate segment setpoint (bit 0)" ... " Acvate segment setpoint´(bit 3)" in compli-
ance with the following truth table:
Acvate segment setpoint Selecon
Bit 3
0x2631:029
(P400.29)
Bit 2
0x2631:028
(P400.28)
Bit 1
0x2631:027
(P400.27)
Bit 0
0x2631:026
(P400.26)
Segment Frequency setpoint PID setpoint Torque setpoint
FALSE FALSE FALSE FALSE No segment setpoint selected
FALSE FALSE FALSE TRUE 1 0x4026:001 (P801.01) 0x4026:006 (P801.06) 0x4026:007 (P801.07)
FALSE FALSE TRUE FALSE 2 0x4027:001 (P802.01) 0x4027:006 (P802.06) 0x4027:007 (P802.07)
FALSE FALSE TRUE TRUE 3 0x4028:001 (P803.01) 0x4028:006 (P803.06) 0x4028:007 (P803.07)
FALSE TRUE FALSE FALSE 4 0x4029:001 (P804.01) 0x4029:006 (P804.06) 0x4029:007 (P804.07)
FALSE TRUE FALSE TRUE 5 0x402A:001 (P805.01) 0x402A:006 (P805.06) 0x402A:007 (P805.07)
FALSE TRUE TRUE FALSE 6 0x402B:001 (P806.01) 0x402B:006 (P806.06) 0x402B:007 (P806.07)
FALSE TRUE TRUE TRUE 7 0x402C:001 (P807.01) 0x402C:006 (P807.06) 0x402C:007 (P807.07)
TRUE FALSE FALSE FALSE 8 0x402D:001 (P808.01) 0x402D:006 (P808.06) 0x402D:007 (P808.07)
TRUE FALSE FALSE TRUE Invalid selecon
...
TRUE TRUE TRUE TRUE
Parameter Name / value range / [default seng] Info
0x2631:026
(P400.26)
Funcon list: Acvate segment setpoint (bit 0)
(Funcon list: Setp: Segment b0)
From version 03.00
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 532
Assignment of a trigger for the "Acvate segment setpoint (bit 0)" func-
on.
Selecon bit with the valency 20 for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected
0x2631:027
(P400.27)
Funcon list: Acvate segment setpoint (bit 1)
(Funcon list: Setp: Segment b1)
From version 03.00
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 532
Assignment of a trigger for the "Acvate segment setpoint (bit 1)" func-
on.
Selecon bit with the valency 2
1
for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected
Flexible I/O conguraon
Setpoint change-over
Setpoint source segment setpoints
563

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals